ChatDiagram
Industrial Automation · PLC Ladder Logic · Pump Control

24V Recycle Timer Control for Sump Pump

النوع منطق سُلّميالمعيار IEC 61131-3 Ladder Diagramالمحرّك schematex-ladderآخر تحديث 4‏/10‏/2026
24V Recycle Timer Control for Sump Pump
Drawing preview
السيناريو

A sump pump must run periodically under 24V relay control, starting on high-level float or manual test and repeating on/off cycles until the float clears.

ما الذي يتضمنه هذا الرسم

اقرأ القرارات الكامنة وراءه.

01

Use a parallel OR branch to let the manual test button or high-level float trigger the cycle

02

Deploy a TON pump-on timer and a recycle off timer with an RES instruction to retrigger the cycle

03

Keep the pump relay coil as a discrete output after the on-timer done bit

Use for small sump or bilge pump applications with 24V control relays where an automatic recycle timer reduces short cycling and adds manual test capability.

تصفّح جميع قوالب منطق سُلّمي ←