Drawing preview
السيناريو

A mine truck requests entry at a gate. The gate opens only if dispatch has approved the entry, no emergency stop is active, and no truck is already in the gate zone (a truck-passed sensor resets the latch). A maintenance override can force the gate open.

ما الذي يتضمنه هذا الرسم

اقرأ القرارات الكامنة وراءه.

01

An SR flip-flop latches the gate open from the SET condition until the truck-passed sensor triggers RESET, ensuring the gate stays open long enough for the truck to pass.

02

A maintenance override bypasses the logic to open the gate unconditionally for servicing or emergency access.

Reusable for any gated entry system requiring conditional approval, safety interlock, and manual override.