8 kW rooftop solar with battery backup
This residential solar PV single line diagram shows a practical hybrid system for a home that needs ordinary grid operation and limited outage backup. The rooftop array passes through a DC disconnect to a hybrid inverter, while a lithium battery supplies the inverter on its DC side. The inverter lands through an AC breaker at the main service panel, with a separate feeder serving critical loads.
Open it in the AI editor with a prompt pre-filled — keep what works, change what doesn't.
Scenario
A homeowner needs a permit-ready overview of a grid-connected rooftop system that can keep selected circuits energized during an outage.
Key decisions
- The 8.0 kWdc array feeds a 7.6 kWac hybrid inverter through a 600 Vdc disconnect.
- The battery connects on the inverter DC side using a 48 V, 13.5 kWh rating.
- A 40 A AC breaker lands at the 240/120 V main service panel.
- Only the critical-load panel sits behind the 60 A backup feeder.
When to reuse this
Use this layout for a single-phase home with selected backup loads. Final conductor and overcurrent sizing must be confirmed for the installed equipment and local code.
Frequently asked questions
Why is the battery connected to the hybrid inverter?
What is on the critical-load panel?
Is this a construction drawing?
Tweak it with chat, export PNG/SVG, or fork it for your own use case.