ChatDiagram
Logic gates · Elevator control · Safety interlock

Elevator door and motion interlock logic

This elevator door and motion interlock diagram turns a few basic operating conditions into two outputs. RUNENABLE requires a car call, closed and locked doors, no overload, normal inspection status, and a condition away from a floor. DOOROPENENABLE allows an opening command only when the car is at a floor and the same inhibit conditions are clear.

Tipo Diagrama de puertas lógicasNorma IEEE Std 91/91a-1991Motor schematex-logicActualizado 22/9/2026
Door and motion interlock
Drawing preview
La solicitud

“Draw gate-level elevator interlock logic with car call, door closed, door locked, overload, inspection mode, and at-floor inputs, producing RUN_ENABLE and DOOR_OPEN_ENABLE outputs.”

Entonces pruebaAdd a door obstruction input.Add a maintenance lockout input.
Qué hay en este dibujo

Lee las decisiones que hay detrás.

01

Both closed and locked door signals are required for movement.

02

Overload and inspection mode inhibit normal operation.

03

An at-floor signal prevents a normal run command.

04

Door opening requires the car to be at a floor and not overloaded.

Use this for a digital logic or controls exercise. Actual elevator safety chains use redundant, monitored, safety-rated circuits beyond this conceptual gate diagram.

Explorar todas las plantillas de diagrama de puertas lógicas →

Preguntas frecuentes

Preguntas habituales

Why need both door closed and locked?

They represent distinct conditions; a closed door is not necessarily mechanically locked.

What does inspection mode do?

It inhibits normal automatic motion in this simplified model.

Is overload normally a gate input?

An overload condition commonly prevents normal operation, though implementation is equipment-specific.