Tipo Schema elettricoStandard IEEE Std 315 / ANSI Y32.2Motore schematex-circuitAggiornato 08/09/2026
Blind Contact Water-Level Alarm
Drawing preview
Lo scenario

A blind person fills a cup and needs an audible signal when liquid reaches the desired level, using two probe contacts that close through the water.

Cosa contiene questo disegno

Leggi le decisioni che ne stanno alla base.

01

Used an NPN transistor as a low-side switch triggered by water contact across probe gaps

02

Added a base pulldown resistor to keep the buzzer off when probes are dry

03

Included a flyback diode across the piezo buzzer to protect the transistor

Reuse for any conductive liquid level detection where a battery-powered audible or vibration alert is needed.