A brewery automates beer transfer from a holding tank through a filter into a carbonation tank, then to bright beer storage, using flow transmitters and indicating controllers to modulate two control valves.
이 도면에 담긴 내용
그 이면의 의사결정을 읽어 보세요.
01
Use two independent flow control loops for upstream and downstream transfer lines
02
Select diaphragm-actuated control valves with fail-closed action on beverage lines
03
Measure flow after each control valve to stabilize batch transfer rates