“Create an SFC for a robot pick-and-place cycle: home, move to pick, grip when at pick, move to place, release when at place, then return home after the part is released.”
Entenda as decisões por trás dele.
Each physical motion or grip phase is a separate state.
Position and gripper signals control progression.
The gripper-open command is issued once on release.
Use for a simple cell sequence before adding guarding, faults, and robot-controller handshakes.
Dúvidas comuns
Why use a step for each motion?
Separate steps make the active phase and its completion feedback clear.
What does P mean on an action?
It marks a one-scan pulse action.
Can faults be added?
Yes. A fault step and transitions can model recovery paths.