A Lycoming O-360 installation needs the HOBBS hour meter to run only when oil pressure is present and after a 5-second start delay to avoid recording engine start cranking.

ما الذي يتضمنه هذا الرسم

اقرأ القرارات الكامنة وراءه.

01

Power feeds through a 1 A breaker to protect the HOBBS meter circuit.

02

An oil pressure switch enables the relay coil, so the meter only runs with engine oil pressure.

03

A 5 s time delay relay prevents the HOBBS meter from logging the start sequence.