Hydraulic clamp sequence control circuit
This example shows a simple electrical sequence for a hydraulic clamp. Pressing Cycle Start energizes the clamp relay and its valve solenoid. When the clamp reaches the configured position, a limit switch changes state and energizes a second relay that operates the release-valve solenoid. The example is deliberately small so the relationship between command, feedback, and output stays easy to read. It can help a maintenance technician explain a basic fixture sequence or help a designer sketch the control intent before adding a controller. Real clamp systems often require guard switches, two-hand control, pressure confirmation, timeouts, and a safe release strategy, all of which should be engineered for the actual equipment.
Open it in the AI editor with a prompt pre-filled — keep what works, change what doesn't.
Scenario
A hydraulic clamp that releases after reaching its limit switch.
Key decisions
- Cycle start: A pushbutton begins the clamp command.
- Position feedback: A limit switch signals that the clamp has reached its position.
- Release output: A second relay and solenoid command the release valve.
When to reuse this
Use as a starting control sequence for a fixture or press clamp, then add timing, guarding, and safety logic for the machine.
Frequently asked questions
What is a clamp limit switch for?
Why use a separate release solenoid?
Is this sufficient safety control for a press?
Tweak it with chat, export PNG/SVG, or fork it for your own use case.