Hydraulic clamp sequence control circuit

This example shows a simple electrical sequence for a hydraulic clamp. Pressing Cycle Start energizes the clamp relay and its valve solenoid. When the clamp reaches the configured position, a limit switch changes state and energizes a second relay that operates the release-valve solenoid. The example is deliberately small so the relationship between command, feedback, and output stays easy to read. It can help a maintenance technician explain a basic fixture sequence or help a designer sketch the control intent before adding a controller. Real clamp systems often require guard switches, two-hand control, pressure confirmation, timeouts, and a safe release strategy, all of which should be engineered for the actual equipment.

Typ SchaltplanStandard IEEE Std 315 / ANSI Y32.2Engine schematex-circuitAktualisiert 24.9.2026
Hydraulic clamp sequence control
Drawing preview
Die Anfrage

“Draw a fused 24 V hydraulic clamp control circuit with a cycle-start pushbutton, clamp relay and valve solenoid, a clamp limit switch, and a release relay and valve solenoid.”

Dann probieren SieAdd a pilot lamp that shows the clamp is made.Change the clamp limit switch to normally closed.
Was diese Zeichnung zeigt

Die dahinterstehenden Entscheidungen verstehen.

01Cycle start

A pushbutton begins the clamp command.

02Position feedback

A limit switch signals that the clamp has reached its position.

03Release output

A second relay and solenoid command the release valve.

Use as a starting control sequence for a fixture or press clamp, then add timing, guarding, and safety logic for the machine.

Alle Schaltplan-Vorlagen durchsuchen →

FAQ

Häufige Fragen

What is a clamp limit switch for?

It provides position feedback when the clamp reaches a defined point in its travel.

Why use a separate release solenoid?

It commands the directional valve to move fluid in the direction that opens the clamp.

Is this sufficient safety control for a press?