HYDRAULICS

Hydraulic clamp sequence control circuit

This example shows a simple electrical sequence for a hydraulic clamp. Pressing Cycle Start energizes the clamp relay and its valve solenoid. When the clamp reaches the configured position, a limit switch changes state and energizes a second relay that operates the release-valve solenoid. The example is deliberately small so the relationship between command, feedback, and output stays easy to read. It can help a maintenance technician explain a basic fixture sequence or help a designer sketch the control intent before adding a controller. Real clamp systems often require guard switches, two-hand control, pressure confirmation, timeouts, and a safe release strategy, all of which should be engineered for the actual equipment.

UPDATED 2026-09-24
EXAMPLEHydraulic clamp sequence control circuit
Make this diagram your own.

Open it in the AI editor with a prompt pre-filled — keep what works, change what doesn't.

CASE ANALYSIS

Scenario

A hydraulic clamp that releases after reaching its limit switch.

Key decisions

  • Cycle start: A pushbutton begins the clamp command.
  • Position feedback: A limit switch signals that the clamp has reached its position.
  • Release output: A second relay and solenoid command the release valve.

When to reuse this

Use as a starting control sequence for a fixture or press clamp, then add timing, guarding, and safety logic for the machine.

FAQ

Frequently asked questions

What is a clamp limit switch for?01
It provides position feedback when the clamp reaches a defined point in its travel.
Why use a separate release solenoid?02
It commands the directional valve to move fluid in the direction that opens the clamp.
Is this sufficient safety control for a press?03
No. Press and clamping safety requires a machine-specific risk assessment and appropriate guarded safety controls.
Open this example in the editor →

Tweak it with chat, export PNG/SVG, or fork it for your own use case.