ChatDiagram
Ladder · Traffic Control

Traffic Light Intersection Control

A two-phase traffic light controller: Phase NS runs North-South green for 30 seconds then transitions to yellow; Phase EW runs East-West green for 25 seconds with its own yellow. TON timers drive the phase durations with output gating.

Tipo Lógica de escaleraNorma IEC 61131-3 Ladder DiagramMotor schematex-ladderActualizado 27/5/2026
Traffic Light Intersection Control
Drawing preview
El escenario

A PLC student must implement a two-phase signalized intersection controller as their first timer sequencing lab.

Qué hay en este dibujo

Lee las decisiones que hay detrás.

01

Phase bits (PHASE_NS, PHASE_EW) set/reset by a master sequence rung — decouples phase logic from output logic.

02

Green and yellow share the same phase bit; yellow enabled only when green timer DN fires.

03

XIO on timer.DN ensures each light turns off exactly when its timer expires, preventing simultaneous green outputs.

Add a pedestrian-call XIC to extend the green phase; add a left-turn arrow rung for a 4-phase intersection.

Explorar todas las plantillas de lógica de escalera →