ChatDiagram
pneumatics · motor-control

Pressure Switch Compressor Control

A pneumatic compressor control circuit starts and stops the compressor according to receiver pressure. This control schematic uses a pressure switch as the demand signal. When pressure falls below its cut-in setting, the switch closes and energizes the contactor coil, subject to the stop and overload contacts. The contactor output also powers a run pilot light. At the cut-out pressure, the pressure switch opens and the compressor stops. The motor power circuit, starter rating, and earth connection belong on the associated power drawing. Set the pressure-switch range, overload, and contactor coil voltage for the actual compressor installation. Include manual isolation in the installation documentation.

類型 電路圖標準 IEEE Std 315 / ANSI Y32.2引擎 schematex-circuit更新時間 2026/9/24
Pressure Switch Compressor Control
Drawing preview
需求

“Draw a 24 V pneumatic compressor control circuit with a stop contact, pressure switch, overload contact, compressor contactor relay, and run pilot light.”

接著試試Add a manual start pushbutton.Change the pilot light label to Running.
這張圖裡有什麼

看懂背後的決策。

01Pressure input

The pressure switch requests compressor operation.

02Protection

Put overload protection in series with the contactor coil.

03Status

Feed the run lamp from the contactor output.

Use for the control portion of a compressor that fills a pneumatic receiver.

瀏覽所有 電路圖 範本 →

常見問題

常見問題

What does a compressor pressure switch do?

It closes at a low cut-in pressure to start the compressor and opens at the high cut-out pressure to stop it.

Why include an overload contact?

It opens the control circuit if the motor overload trips, preventing the contactor from remaining energized.

Is this the motor power circuit?

No. It is the low-voltage control circuit; the motor power wiring is shown separately.